ATEX / IECEx Zone Checker

Check whether equipment's ATEX/IECEx marking is actually suitable for the hazardous zone it's going into, or look up what a zone requires. Based on ATEX 114/153 and EN 60079 series classification.

Select an environment and zone to see the minimum equipment requirement.
MINIMUM EQUIPMENT
Allowed categories
Allowed EPLs
Equipment marking
What the area actually requires
This checks the three things a marking must satisfy together: category/EPL for the zone, gas or dust group, and temperature class. All three must pass — equipment isn't averaged across criteria.
SUITABILITY
Type of explosion protection
CodeMeaningApplies to
Ex dFlameproofGas (electrical)
Ex eIncreased safetyGas (electrical)
Ex iIntrinsic safetyGas (electrical)
Ex mEncapsulationGas (electrical)
Ex pOverpressureGas (electrical)
Ex qPowder fillingGas (electrical)
Ex oLiquid immersionGas (electrical)
Ex nA, nR, nCNon-arcing, restricted breathing, enclosed constructionGas (electrical)
Ex op isOptical radiationGas (electrical)
Ex t / tD A2xProtection by enclosureDust (electrical)
Ex p / pDOverpressureDust (electrical)
Ex i / iDIntrinsic safetyDust (electrical)
Ex m / mDEncapsulationDust (electrical)
bControl of ignition sourceGas or dust (non-electrical)
cConstructional safetyGas or dust (non-electrical)
kLiquid immersionGas or dust (non-electrical)
Ex hMechanical protection with b, c, or kGas or dust (non-electrical)
dFlameproofGas or dust (non-electrical)
Gas / dust group
GroupAllowed in area with
IIAIIA gases (e.g. methane, propane, acetone, kerosene, petrol)
IIBIIA and IIB gases (e.g. ethyl glycol, ethylene, ethanol)
IICIIA, IIB, and IIC gases (e.g. hydrogen, acetylene)
IIIAIIIA fibres (>0.5mm)
IIIBIIIA and IIIB dust (non-conducting, <0.5mm)
IIICIIIA, IIIB, and IIIC dust (conducting, <0.5mm)
Temperature class
ClassMax surface tempAllowed in area with
T1450°CT1
T2300°CT1, T2
T3200°CT1, T2, T3
T4135°CT1, T2, T3, T4
T5100°CT1, T2, T3, T4, T5
T685°CT1, T2, T3, T4, T5, T6
Hand tools (EN 1127-1, Annex A)
ZoneSingle sparks (hand tools)Shower of sparks (sawing, grinding)
0 / 20Not allowedNot allowed
1Limited allowed *1Not allowed
2AllowedNot allowed
21 / 22AllowedLimited allowed *2
*1 Steel tools not allowed with gas group IIC, H₂S, CO, or ethylene oxide.
*2 Protect the workplace and remove accumulated dust, or keep the workplace wet.
Clothing (CLC/TR 60079-32-1, 11.5)
ZoneRequirement
All zonesAntistatic shoes (consider the surface); don't put clothes on or off in the area
Zone 0 and 1Anti-static clothing
Zone 2, 20, 21, 22No special requirements, except for very sensitive gases or dusts
ATEX 114 — directive for manufacturers of equipment, safety devices, and protective systems.
ATEX 153 — directive for employers/end-users, covering safety and health protection of workers.
Sequence of measures
  1. Prevent the explosive atmosphere — remove fuel or oxygen
  2. Prevent ignition sources — ATEX equipment, spark-free tools, etc.
  3. Limit consequences — pressure relief, isolation, suppression
The explosion triangle: an explosive atmosphere needs explosive material, oxygen, and a source of ignition together. Remove any one and there's no explosion risk — this is why the sequence above starts with prevention rather than protection.